An Introduction to the Laboratory
Microscopy
The microscope was first applied to biological material in the early seventeenth
century by researchers such as Robert Hooke and Antoni van Leeuwenhoek, and
remains a pivotal tool in learning about biology today.
Over the course of this year, you will be using two different types of microscope:
OR
These microscopes are delicate and expensive instruments and must be treated
with care.
When using a Light Microscope please keep the following
in mind:
- When transporting your microscope always pick it up by the arm.
Hold it upright and support the base with your free hand.
- The arm supports an inclined body tube, which in turn supports the
magnifying elements of the microscope. At the end of the tube is the ocular,
one of the magnifying elements. The other magnifying elements are screwed
into a revolving nosepiece at the bottom of the body tube; these are called
objectives.
- Underneath the body tube and nosepiece is a flat plate, the stage,
upon which objects to be examined are placed. Directly beneath the stage opening
you will notice a system of lenses, the condenser,
which serves to concentrate the light from the illuminator
below.
- Light plays an extremely important role in the operation of a compound
microscope. The critical importance of light makes necessary its careful
adjustment, and several controls are available for this purpose.
The iris diaphragm may be found just below the condenser lens system.
This control is one of the most important on your instrument.
- Changes and adjustments in the focus, which are necessary when an object
is first placed on the microscope and essential in order to perceive depth,
are accomplished by means of coarse and fine adjustment knobs
usually located on the arm. Note that the fine and coarse focus knobs are
separate on some of our microscopes and combined on others.
You should be able to locate the terms in bold on the image of the light
microscope above, or click
here if you are having problems.
Keep the following in mind when using a Stereoscopic Microscope:
- The depth of field is much greater than with the compound microscope, which
allows objects to be view in three dimensions
- The optics do not invert images
- To focus close your left eye and adjust the focus of the image viewed
with the right eye. Open your left eye and close your right eye and adjust
the focus for the left eye using the secondary focus ring located on
the left ocular.
- All of our stereo microscopes are binocular. To obtain the correct
interpupilary distance for your eyes you must adjust the distance between the
two oculars by gently pushing or pulling the oculars until you see the object
as a single image.
- Note that the dissecting microscope is not parfocal and must be re-focused
when the magnification is changed
Consider the following questions for both the light microscope and the
stereoscopic microscope
- When you move the slide to the right while looking into the microscope, which way does the image appear to move?
- Which way does the image move when you move the slide toward you?
- Away from you?
Click here to view the letter F slide as seen through a compound light microscope
Click here to view the letter F slide as seen through a stereoscopic microscope